Toshiba B-EX Label Maker User Manual


 
41
[Product] Group
[Printer Serial No.]:
The serial number specific to the printer is displayed.
This setting cannot be changed.
[SHELL]:
The status of the SHELL function is displayed.
This setting cannot be changed.
[Sensor] Group
[Reflective Sensor Threshold Select]:
Select how to set the threshold for the reflective sensor.
Default Command Set
Options Manual Set, Command Set
[Reflective Sensor Threshold]:
Set a fine adjustment value for threshold to the reflective sensor output in units of 0.1 V.
Default 1.0 V
Range 0.1 to 4.0 V
[Transmissive Sensor Threshold Select]:
Select how to set the threshold for the transmissive sensor.
Default Command Set
Options Manual Set, Command Set
[Transmissive Sensor Threshold]:
Set a fine adjustment value for threshold to the transmissive sensor output in units of 0.1 V.
Default 1.4 V
Range 0.1 to 4.0 V
[Ribbon Adjustment] Group
[Drive Voltage (Take-up)]:
Fine adjust the ribbon take-up motor voltage (torque).
The fine adjustment value set by the Ribbon Motor Drive Voltage Fine Adjust command [RM] is
displayed in the left box.
When the parameter is not retrieved, the value in the left box becomes zero (0).
Default 0
Range -15 to +10
[Drive Voltage (Feed)]:
Fine adjust the ribbon feed motor voltage (torque).
The fine adjustment value set by the Ribbon Motor Drive Voltage Fine Adjust command [RM] is
displayed in the left box.
When the parameter is not retrieved, the value in the left box becomes zero (0).
Default 0
Range -15 to +10
[RTC] Group
[Date Time]:
The current date and time programmed for the RTC module are displayed.
This setting cannot be changed.
[Battery Check]:
Select whether to enable or disable the battery check function.
Default Disable
Options Disable, Enable
[Renewal]:
Select the timing when the date and time are updated during printing.
Default Batch
Options Batch, Page