Appendix 3 Compatibility with the communications func-
tion of the VF-S9
To provide consistency in communications procedures, the communications function of the VF-S11
series of inverters has been designed based on the protocols used for the Toshiba VF-S9 series of
inverters. With regard to compatibility, however, VF-S9 users should check the items described be-
low before using the communications function of their inverters.
To VF-S9 inverter users:
Some parameters of the VF-S9 are different from those of the VF-S11 in function or adjustment
range (upper and lower limits), even though they have the same title or the same communication
number. So, when accessing a parameter, consult the VF- S9 inverter’s instruction manual to see if
the parameter is identical to the corresponding parameter of the VF-S11. If the parameter differs,
modify the computer program to suit your inverter. To avoid hazards, never copy parameters from
one model of inverter to another.
Comparison of communication-related items
The table below gives a comparison of communication-related items to be kept in mind when re-
placing VF-S9 inverters with VF-S11 inverters or when connecting VF-S9 inverters and VF-S11 in-
verters to the same network. It does not cover any items common to the VF-S9 and VF-S11 series of
inverters.
Model
Item
VF-S9 VF-S11 Reference
Data processing time of
inverter
About 8 ms
(This is only standard time, not guarantee
time.)
maximum 20ms Appendix 2
Notice
Do not use communications programs written for another series of inverters.
Even though parameters have the same title and the same communication number, they may be different
in function. When using a parameter, always check its specifications in the instruction manual for your
inverter. If the specifications of the parameter differ, modify the computer program to suit your inverter.
To avoid hazards, do not copy parameters from one model of inverter to another.
Even though parameters have the same titles and communication numbers, they may be different in
function.