TP-Link T1500-28PCT Switch User Manual


 
43
Chapter 7 System Log Commands
The log information will record the settings and operation of the switch respectively for you to
monitor operation status and diagnose malfunction.
logging buffer
Description
The logging buffer command is used to configure the severity level and the
status of the configuration input to the log buffer. To disable the logging buffer
function, please use no logging buffer command. Local Log is the log
information saved in the switch. It has two output channels, that is, it can be
saved to two different positions, log buffer and log file.
The log buffer indicates
the RAM for saving system log and the information in the log buffer can be got
by show logging buffer command. It will be lost when the switch is restarted.
Syntax
logging buffer level
no logging buffer
Parameter
level —— Severity level of the log information output to each channel. There are
8 severity levels marked with values 0-7. The smaller value has the higher priority.
Only the log with the same or smaller severity level value will be output. By
default, it is 6 indicating that the log information with level 0-6 will be saved in
the log buffer.
Command Mode
Global Configuration Mode
Example
Set the severity level as 5:
T1500-28PCT(config)# logging buffer 5