Command Reference 10-47
Serial Communications Parameters
The following parameters configure the connection between the
NETServer and the devices attached to its ports (modems).
These parameters are independent of port type (such as user
login and network dial in)
S0 only: Setting DIP switch 3 on (down) will override these
settings and force the following:
Port Type: Login
Baud: As configured by DIP switches 1 and 2
Byte Format: 8/N/1
Modem Control: Off
Port Speed
This is the baud rate of the port. You can set up to three baud
rates. For connecting the port to modern data communications
equipment, all three rates should be the same. However, some
older equipment may require multiple rates. Use the following
command:
set s<port #> speed <#> <baud rate>
The <#> can be 1, 2, or 3. If not specified, 1 is assumed. When a
break character is received, the port will cycle through the three
assigned rates. The baud rate can be any one of the following:
115200, 57600, 38400, 19200, 9600, 4800, 2400, 1200, 600, or 300.
Databits
This is the number of data bits per character the port is config-
ured for. The default is 8.
set s<port #> databits <
8
|
7
|
6
|
5
>
Stopbits
This is the number of stop bits. The default is one.
set s<port #> stopbits <
1
|
2
>