5-4 Network Dial In Access
NETServer Dial-In (Detailed Setup)
To set up the NETServer software for this application:
Configure at least one port
Create a user table entry for each user
Configuring a Port
Ports used for this type of dial-in access should be configured as
Network ports that allow dial in.
Step 1 - Port Type
Set the port type. Usually, you would configure the port as a
network dialin port. If you will be configuring dialback users,
or will also be using the port for dial out routing, configure the
port as network twoway. Use the following command:
set s<port #> network <
dialin
|
twoway
|
hardwired
>
Hardwired: Setting a port to Hardwired tells the NETServer’s
operating software that you are establishing a synchronous
connection via a serial cable. Since s0 is the only serial port, this
is the only port for which the hardwired setting is valid.
If you configure s0 as Hardwired, set the following parameters
and go to Step 4. (For an explanation, see Ports Table, Hardwired
Port Parameters in Chapter 10).
IP Address Routing
IPX Network Number MTU
Netmask Compression
Protocol