OVERVIEW AND PRINTER SETUP
FSL cross reference for the coax configuration page
The default settings on the coax configuration page are printed
using references to the FSL (Function Select via Line) command
numbers. A list of the items that are printed on the
configuration page is shown in table 1-2. Next to each item is an
abbreviated configuration command name in parentheses.
Table 1-2. Command numbers and names
Func # 1 set to 4 (IBM buffer size) Func # 32 set to 0 (Non-SCS valid FF)
Func # 2 set to 6 (Lines per inch) Func # 33 set to 0 (Non-SCS A.F, at end of job)
Func # 3 set to 10 (Characters per inch) Func # 34 set to 1 (Last LF as FF)
Func # 5 set to 62 (Max page length) Func # 36 set to 0 (Suppress IBM ctrl code)
Func # 6 set to 132 (Max print line) Func # 37 set to 1 (Printer Emulation)
Func # 7 set to 1 (Set case) Func # 38 set to 1 (Communication feature)
Func # 8 set to 0 (Set LU1 language) Func # 44 set to 1 (Suppress CR & SP)
Func # 10 set to 0 (Set page format) Func # 46 set to 12 (Set IRQ timer)
Func # 11 set to 2 (Default paper path) Func # 47 set to 1 (ESC mode selection)
Func # 12 set to 3 (Default paper size) Func # 49 set to 0 (Restrict access)
Func # 13 set to 1 (Set wrap/Cut option) Func # 50 set to 0 (FF after timeout)
Func # 14 set to 1 (Enable graphic option) Func # 73 set to 0 (Select translate table)
Func # 19 set to 0 (Set simplex/duplex) Func # 78 set to 1 (Select APL translate table)
Func # 25 set to 0 (FF before local copy) Func # 79 set to 0 (not used)
Func # 26 set to 1 (FF after local copy) Func # 89 set to 0 (Enable page offset)
Func # 27 set to 0 (Non-SCS print image) Func # 98 set to 1 (Enable APO)
Func # 28 set to 0 (Non-SCS CR at MPP+1) Func # 110 set to 1 (not used)
Func # 29 set to 0 (Non-SCS NL at MPP+1) Func # 111 set to 0 (not used)
Func # 30 set to 1 (Non-SCS valid FF+data) Func # 112 set to 0 (not used)
Func # 31 set to 1 (Non-SCS valid FF at end) Func # 113 set to 1 (not used)
Func # 119 set to 2 (Enable Auto paper size
configuration)
Func # 120 set to 1 (settings at power up)
FSL Y4, Set Default Line Spacing (Line Spacing - Single, Double),
can be changed, but does not show up on the configuration
report.
FSL Y9, Active GFID, appears on the bottom half of the
configuration page.
For more information on these FSL commands, refer to the
“Function Select via Line commands” chapter. This chapter
includes detailed information on the definition and use of the FSL
commands.
For more information on the use of the Coax Configuration and
Resource Utility, refer to the “Coax Utility” chapter in this
manual.
XEROX MRP FAMILY COAX COMMAND REFERENCE 1-9