Zebra Technologies S400 Printer User Manual


 
Zebra S400 & S600 User’s Guide 67
®®lcà
56&RQQHFWRU7HFKQLFDO,QIRUPDWLRQ
NOTE: When XON/XOFF handshaking is selected, data flow is
controlled by the ASCII control codes DC1 (XON) and DC3
(XOFF). The DTR control lead has no effect.
,QWHUFRQQHFWLQJWR'7('HYLFHV
The printer is configured as data terminal equipment (DTE). To connect
the printer to other DTE devices (such as the serial port of a personal
computer), use an RS-232 null modem (crossover) cable. Figure 31 shows
the required cable connections.
,QWHUFRQQHFWLQJWR'&('HYLFHV
When the printer is connected via its RS-232 interface to data
communication equipment (DCE) such as a modem, a STANDARD
RS-232 (straight-through) interface cable must be used. Figure 32 shows
the connections required for this cable.
RS-232 Connector Pinouts
Pin. No. Description
1 Not used
2 RXD (receive data) input to the printer
3 TXD (transmit data) output from the printer
4 DTR (data terminal ready) output from the printer — controls when the host
may send data
5 Chassis ground
6 DSR (data set ready) input to the printer
7 RTS (request to send) output from the printer — always in the ACTIVE
condition when the printer is turned on
8 Not used
95 V Fused