Accton Technology EP3003 Printer User Manual


 
Print Server User’s Guide
4
LED Indicators
There are two LED indicators on the top on the Print Server unit. The red LED is the
Status/Error indicator. The green LED is the Power/Link indicator. See the previous
figures to locate the LEDs on your model. The LED indicator modes are described in
the following table.
Green LED Red LED Status Description
Solid Off Solid Off No power.
Solid On Solid On Hardware error.
Solid On Solid Off Normal operation.
Flashing Off Transmitting or receiving
packets from the network.
Table 1:- LED Indicators
10/100BaseT Switches
Models supporting 10BaseT and 100BaseT have 2 DIP switches. See the previous
diagrams to locate these switches. Operation of these switches is described below.
Switch Description
1 Auto Negotiation Switch.
When ON (UP position), the device will select
10BaseT/100BaseT and Full/Half Duplex as required. The
recommended position is ON; switches 2 & 3 are disabled
when Auto Negotiation is ON.
2 10/100BaseT Manual Select Switch.
Set UP for 100BaseT or DOWN for 10BaseT.
Switch 1 must be OFF for this switch to function.
3 Full/Half Duplex Switch.
Set UP for Full duplex operation or DOWN for Half Duplex
operation.
Switch 1 must be OFF for this switch to function.
Table 2:- DIP Switches