Acer MU.R230E.001 Server User Manual


 
Appendix B: Rack mount configuration122
Elevated operating ambient temperature
The maximum operating temperature of the system is 35°C (95°F).
Careful consideration should be given to installing the system in
an environment compatible with the 35°C (95°F) maximum
ambient temperature.
Reduced airflow
The amount of airflow required for the safe operation of the
equipment should not be compromised when installing the system
in a rack.
Mechanical loading
Exercise care when mounting the system in a rack to avoid any
accidents.
Circuit overloading
Appropriate consideration should be given when connecting the
supply circuit to the system to avoid any circuit overload. The
system name plate rating should be used when addressing
concerns about circuit overload.
Rack mount kit
The rack mount kit components and their respective function is listed
on the table below.
Component Quantity Usage
Mounting rails 2 Allows the server to slide in and out of the
rackmount for maintenance purposes.
Each mounting rail consists of the
following:
Fixed outer rail. Attaches to system rack
with M6 x 13 screws.
Inner rail. Attaches to the sides of the
server with M4 x 5 screws.
Middle sliding piece has a steel ball
gearing to control server movement
from and into the rackmount.