ADC ICX-250 Switch User Manual


 
12 System Basics Installing the ICX-250
ADCP-62-023 Issue 1, September 1998
© 1998, ADC Telecommunications, Inc.
Wall Mounting
Prior to wall mounting check to see if the environment is stable and free
from any extreme temperatures, humidity or vibrations of any sort. The
unit should be mounted with the fan to the top with at least 2 inches of
clear space on the sides, above, and below for adequate air flow. Allow at
least 6 inches for cable clearance and access to switches.
When attaching unit(s) to a wall make sure that appropriate fasteners such
as masonry anchors, heavy duty wood screws or expansion bolts are used
for heavy objects.
!!ATTENTION!!
Set all options prior to installing
mounting brackets, top cover cannot be removed
once brackets are in place.
Note:
Additional support hardware may be necessary
(not included with unit) to secure the unit properly to
the wall. If the surface is not solid enough to hold the
unit and attached cabling, it is recommended that a
small piece of 3/4” plywood be fastened to the wall before
attaching the unit. This will help ensure a more stable environment
.
ANGLE
BRACKET
Wall