28 Configuring the ICX-250 Switches
ADCP-62-023 Issue 1, September 1998
© 1998, ADC Telecommunications, Inc.
FXS Ports - Trunk Conditioning
(
DIP switches - internal)
Description:
S6 position 6 and S7 position 6 selects the trunk conditioning state.
Factory Setting:
IDLE
Idle:
In the event of an alarm condition in the T1 connection to the network, the FXS Ports will be
put into the idle state immediately and remain in this condition until the T1 has been restored.
Idle Immediate/Busy Delay:
In the event of an alarm condition in the T1 connection between the
ICX-250 and the network, the FXS Ports will be put into the Idle state immediately for 3 seconds
and then put into the Busy state and remain in this condition until the T1 has been restored.
The DIP switch settings shown in the illustration above are for Switch S6 and S7.