ADC ICX-250 Switch User Manual


 
External DIP Switches Configuring the ICX-250 35
Issue 1, September 1998 ADCP-62-023
© 1998, ADC Telecommunications, Inc.
Data Port 1 and 2 - Number of Timeslots
(
DIP switch - back
)
IICX-250 - Rear Panel
Switch numbers S1 through S5 are shown on the board within the unit.
Description:
S2 positions 1, 2, 3, 4 and 5 (Data 2 - DIP switch) sets the port parameters for Data
Port 2. S3 positions 1, 2, 3, 4 and 5 (Data 1 -DIP switch) sets the port parameters for Data Port 1.
Both DIP switches are used for Network Data Bandwidth.
Factory Setting:
All switches are set to zero (data ports inactive).
Number of Timeslots:
Selects the number of consecutive timeslots that data from Data Port 1 and/
or 2 will be mapped onto. Please refer to Decimal/Binary Conversion Table (see page 36) for Data
Port Configuration to aid in selecting
N
. Drawing above indicates switch settings if timeslot N = 13.
Selected quantity of timeslots x 64K = Data Port Bandwidth.
Note:
Binary numbers are used to select the number
of timeslots and starting timeslots.
120 VAC–.6A 60Hz
24/48 VDC
+ – G
T1
Rx
Tx
T1 Line
T1Data 2Data 2Data 11121324
ON DIP
10
1
23456789101112
Alm.
Data 1
FXS Loopback
FXS Loop Pairs
S5 S4 S3 S2 S1
11271-A
Data 1 / Data 2