ADC MM701G2 Network Card User Manual


 
Appendix A: Command Line Interface Access April 14, 2006
A-24 MM70xG2-UM-03
2 View the current statistics, as described below:
Operational State
Indicates the current mode of the modem. Operational states include:
Handshaking—indicates that the modem is negotiating with the DSLAM or the other modem
Training—indicates that the modem is learning the connection parameters
Show time—indicates the G.shdsl connection is operational
Data Rate
Indicates the bit rate for this transmission on the G.shdsl connection.
DSP Version
Identifies the version of G.shdsl firmware driver used for this modem.
Transmission Power
Indicates the local transmission power in decibels.
Receiver Gain
Indicates the amplifying factor for incoming signal in decibels.
Local SNR Margin
Indicates the current value for the SNR margin in decibels.
Loop Attenuation
Indicates the current and approximate loop attenuation (loop signal loss) in decibels.
Framer Sync
Indicates the current status of G.shdsl framer synchronization.
Step Action