Agilent Technologies N-Series Printer User Manual


 
User’s ManualPage 4-10
Print Job
COMMAND:COMMAND:
COMMAND:COMMAND:
COMMAND: s
+P+P
+P+P
+P
,optional comment ,optional comment
,optional comment ,optional comment
,optional comment
d
RANGE:RANGE:
RANGE:RANGE:
RANGE:
132 Characters for optional comment132 Characters for optional comment
132 Characters for optional comment132 Characters for optional comment
132 Characters for optional comment
The Print Job command marks a job boundary, purges the last page
buffer and begins printing. Printing is allowed using only one font
orientation; an orientation change causes a new job, because it is an
implied job boundary.
This command will cause a Configuration/Status Page to print if: 1) an
error occurs and the Configuration/Status Page switch is enabled, or 2)the
previous command included a comma. An optional comment of up to 132
characters, if entered, will be printed on the Configuration/Status Page.
Print Job (Mixed Orientation)
COMMAND:COMMAND:
COMMAND:COMMAND:
COMMAND: s
+Q+Q
+Q+Q
+Q
,optional comment ,optional comment
,optional comment ,optional comment
,optional comment
d
RANGE:RANGE:
RANGE:RANGE:
RANGE:
132 Characters for optional comment132 Characters for optional comment
132 Characters for optional comment132 Characters for optional comment
132 Characters for optional comment
This command marks a job boundary, but printing is allowed using
multiple font orientations.
This command is interpreted as if it were a Print Job command.
Reset
COMMAND:COMMAND:
COMMAND:COMMAND:
COMMAND: s
+X+X
+X+X
+Xd
RANGE:RANGE:
RANGE:RANGE:
RANGE:
N/AN/A
N/AN/A
N/A
The Reset command ends all types of jobs, marks a job boundary, tells
the printer that any data that follows it is part of a new job, and returns the
printer to its start-up state. All format parameters are reset to their default
settings, and all font and form assignments are erased. If several
documents are to be printed with the same parameters, the Print Job
command should be used at the beginning of each document, but the
Reset command should not be used.
If Reset is used to exit Data Monitor mode, and if Data Monitor mode
was introduced with a UDK, the same UDK must be used to introduce a
Reset. For example, if Data Monitor mode was introduced as follows:
=UDK=**+D