Asante Technologies 5308F Switch User Manual


 
Installation
Page 2-4
Rack Mounting/
Desktop
Placement
The IntraSwitch 5308FL can be installed in a standard 19-inch
equipment racks. It can also be placed on a horizontal surface
with support capabilities of 11 pounds (5 kilograms).
Equipment Rack
Installation
To install the IntraSwitch 5308FL in an equipment rack:
Important! Disconnect all cables from the
IntraSwitch 5308FL before continuing.
1
Place the IntraSwitch 5308FL on a stable, flat surface.
2
Locate a rack-mounting bracket (supplied) and
place it over the mounting holes on one side of
the unit, as shown in Figure 2-1.
Figure 2-1 Mounting rack bracket on the IntraSwitch 5308FL
3
Insert four screws (supplied) into the holes and
tighten with a Phillips screwdriver.
4
Repeat the two previous steps for the unit’s
other side.
5
Place the IntraSwitch 5308FL in the equipment rack.
Important! Make sure the IntraSwitch 5308FL
is supported until all four mounting screws for
each bracket are secured to the equipment rack.