Asante Technologies 5308F Switch User Manual


 
Configure SNMP Parameters
Page 5-19
Table 5-8 SNMP Parameter Settings
Setting Description
SNMP Read
Community
The IntraSwitch 5308FL’s SNMP read
community string.
The read community string is a single word
that defines access rights for reading SNMP
data objects.
The default setting is public.
SNMP Write
Community
The IntraSwitch 5308FL’s SNMP write
community string.
The write community string is a single word
that defines access rights for writing SNMP
data objects.
The default setting is private.
Trap Authentication The status of the SNMP agent to generate
authentication traps.
Note:
An authentication trap occurs when a
network station with an invalid community
string attempts to access the IntraSwitch
5308FL.
The default setting is disabled.
SNMP Trap Receivers The IP addresses of the network management
stations that can receive traps. Normally,
these addresses are the same as your network
management software systems’ IP
address(es).
Important! A maximum of four traps
receivers is allowed.