ATEN Technology IP8000 Computer Hardware User Manual


 
Appendix
85
Administrator Login Failure
If you are unable to perform an Administrator login to the IP8000 (because the
Username and Password information has become corrupted, or you have
forgotten it, for example), there is a procedure you can use to clear the login
information.
Note: Performing this procedure also returns all settings to their defaults.
To clear the login information (and return all settings to their defaults), do the
following:
1. Power off the IP8000 by unplugging its power adapter cable.
2. Power off the server that the IP8000 is installed in and remove its housing.
3. Short the jumper on the IP8000 labeled J2 Default Password.
4. Power on the IP8000 by plugging its power adapter cable back in. Wait a
few seconds, then unplug it again.
5. Remove the jumper cap from J2.
6. Close the housing and start the server back up.
7. Plug the IP8000’s by power adapter cable back in.
After you complete these steps, you can use the default Username and
Password (see page 13) to log into the IP8000.
ip8000.book Page 85 Friday, May 9, 2008 10:39 AM