Avery 6057 Label Maker User Manual


 
For the On-Demand sensor, the range is between 0 and 5.0. When you hold a label over the
sensor, the values change on the display. When the sensor is blocked by a label, the value is
at the high end of the range. When the sensor is not blocked, the value is zero or close to zero.
On-Demand
Sensor
4.
The value listed for PH Temperature is the current temperature of the printhead. The valid
range is between 5 and 60 Celsius. The temperature of the printhead depends upon the
number of labels printed and the operating environment. If the temperature is greater than
60, the printer does not print.
Note: If the value is not within the ranges, make a note of the values and call Service.
5. Touch OK to return to the Printer Diagnostics window.
OR
Touch X to return to the desktop.
Using Printer Diagnostics 6-7