Avery 6057 Label Maker User Manual


 
8. Set the AIM Duration, which is the duration of the aiming beam when the scanner is
activated. The range is 0.0 - 9.9 seconds in .1-second increments (0 disables the AIM
feature). The default is 0.
9. Set the Linear Security, which is how many times to scan the same bar code to determine a
successful read. The range is 1 – 4. The default is 1.
10. Enable Bi-Directional Redundancy, which specifies that good scans must occur in both
directions (forward and reverse) for the scan to be complete.
11. Touch OK to return to the Scanner Configuration window.
Setting a Tone for Good or Bad Scans
1. Touch the Emerald key to access the Start Menu, select Settings, Control Panel, and User
Notification.
2. Select the Event to add sound.
3.
Touch Edit.
4. Change the LED settings (Color, Mode, ON/OFF Time and Cycles), if necessary. The default
LED color setting is yellow for a bad scan and green for a good scan.
Configuring the Scanner 7-3