Barco R9001560 Projector User Manual


 
8-3
Random Access Adjustment Mode
5976052 BARCOREALITY 9300 070999
Select with or
<ENTER> to toggle
or to change value
<EXIT> to return
EDIT FILE OPTIONS
Source number 1
Clamp position [leading]
Clamp delay 0
Clamp width 10
Field polarity [pos]
Field select [both]
Vertical refresh [sync]
Vert. sync polarity [leading]
The file name will be displayed in the upper right corner.
The following items can be adjusted :
Total quantity horizontal pixels
Active quantity horizontal pixels
Horizontal start in pixels
Horizontal period in µs (is automatically adapted during the installation of a file with LOAD)
Total vertical lines (is automatically adapted during the installation of a file with LOAD)
Active vertical lines
Vertical start in lines
Interlaced : toggle on/off (is automatically set to its correct position during the installation of
a file with LOAD)
EDIT FILE xga.s30
HORIZONTAL
TOTAL 1344 PIXELS
ACTIVE 1024 PIXELS
START 296 PIXELS
PERIOD 20.678 µS
VERTICAL (FIELD)
TOTAL 806 LINES
ACTIVE 768 LINES
START 36 LINES
INTERLACED [OFF]
READ AMDS
OPTIONS
, , , <ENTER>, <EXIT>
All settings can individually be changed.
1 Push the cursor key é or ê to select an item.
The color of the selected item will change and follow one of the three methods to change the value.
a. method 1:
1 press ENTER to activate the digits
2 enter directly with the numeric keys on the RCU or local keypad the new value or
b. method 2:
1 Press ENTER to activate the digits
2 Push the cursor key è or ç to select the changing digit.
3 Push the cursor key é or ê to scroll to desired digit.
4 When finished press ENTER to confirm.
c. method 3
1 Counting up or down by pushing the cursor key è or ç .
How to find the correct values for the displayed item?
During the installation of a file with LOAD, the horizontal period, the total number of vertical lines and the interlaced mode are automatically
measured and filled in in the menu table. These values will be available when starting up the EDIT procedure of an active file.
(Caution : Do not adjust these settings on an active file, they are used to identify the input source file.)
If the value for "Horizontal Total Pixels" is wrong, sampling mistakes (small vertical bars in the projected image) will be seen in the image.
Select "Total" and adjust the pixel quantity. Adjust for zero bars (hint: if the number of bars increase, adjust in the other direction).
The "Active Pixels" : determine the width of the window on the screen. This value is normally given in the source specifications. If not,
adjust until full image is displayed (no missing pixels).
"Horizontal Start" : number of pixels between the beginning of the input signal and the start of the video information in the signal.
"Horizontal Period" : already filled in with the correct value when active file. (see caution above).
The "Vertical Total Lines" are already filled when an active file is selected to be edited (see caution above).
The "Active Lines" : number of horizontal lines determining the height of the projected image. This value is normally given in the specification
of the source. If not, adjust until full image height is displayed (no missing lines)
Vertical start : number of lines between the start of the input signal and start of the image on the screen.
Interlaced [On] or [Off] : this selection is automatically filled when active file has to be edited. If the image is wrong due to mismeasurement,
use the ENTER key to toggle between [On] and [Off]. (for interlaced images, 1 frame contains 2 fields).
Read AMDS
AMDS = automatic mode detection & synchronisation
During the installation of a file with LOAD, the system automatically measured the horizontal period, the total vertical lines and the interlaced
mode.
When selecting Read AMDS, the system remeasures the above indicated items.
Options
Source Number : The source number of a non-active source can be changed to any other
source number. This makes it possible to create a file for future source numbers.
Clamp Position : Clamping determines the black level of the signal.
The clamp pulse can be related to the leading or the trailing edge of the sync pulse. Use the
ENTER key to toggle between [leading] and [trailing].
Clamp Delay : The time between the leading edge of the clamp pulse and the locked edge of
the sync pulse.
Can be any value between 0 and 255. Change the value by pushing the cursor key è or ç.