Black Box ET10000A Network Hardware User Manual


 
Specifications
ETEP Installation Guide 23
Table 9 ET1000A Mechanical and Environmental Specifications
Category Specification
Interfaces (2) Gigabit Ethernet ports for encrypting and decrypting traffic
(single mode, multimode, or copper)
10/100 Mbps auto-sensing Ethernet LAN port for management
RS-232C port for management
(1) Auxiliary Gigabit port for data traffic (not enabled)
(1) Gigabit Ethernet port for management (not enabled)
ET1000A
Electrical/Mechanical
Dimensions
19 inch rack mount design
1U tamper evident chassis
Dimensions: 1.75” H x 17” W x 10” D
Weight: 6 pounds
100-240 VAC @ 4 amps, 50/60 Hz, auto-sensing
Nominal power dissipation: 65 watts
Nominal input current: 1.0A
Thermal power: In-rush 310 BTU/hour, steady state 280 BTU/hour
ET1000A
Electrical/Mechanical
Dimensions
19 inch rack mount design
1U tamper evident chassis
Dimensions: 1.75” H x 17” W x 15.5” D
Weight: 10 pounds
100-240 VAC @ 3-1.5A, 47-63 Hz, auto-sensing
Nominal input power: 72 watts
Maximum power: 90 watts
Nominal input current: 0.65 A @ 110V
Thermal power, single power supply: In-rush 266 BTU/hour, steady
state 222 BTU/hour
Thermal power, dual power supplies: In-rush 440 BTU/hour, steady
state 263 BTU/hour
Environmental Operating temperature: 0 to 40 degrees C (32 to 104 degrees F)
Operating humidity: Up to 90% (non-condensing)
Operating altitude: -200 to 10,000 feet AMSL
Regulatory See “ET1000A Regulatory Information” on page 81 and “ET1000A
Regulatory Information” on page 81.