Brother FAX-8070P Printer User Manual


 
Appendix–38
Bar Code Human Readable Line On or Off
n = “r0” or “R0” Human readable line OFF
n = “r1” or “R1” Human readable line ON
Default: Human readable line ON
(1) “T5” or “t5”
(2) “T6” or “t6”
(3) “T130” or “t130”
(4) “T131” or “t131”
Default: Human readable line OFF
All others
This parameter specifies whether or not the printer prints the human
readable line below the bar code. Human readable characters are always
printed with OCR-B font of 10 pitch and all the current character style
enhancements are masked. Note that the default setting is subject to the bar
code mode selected by “t” or “T”.
Quiet Zone
n = “onnn” or “Onnn” (nnn = 0 ~ 32767)
Quiet Zone is the space on both sides of the bar codes. Its width can be
specified using the units that are set by the “u” of “U” parameter. (For the
description of “u” or “U” parameter, see the next section.) The default setting
of Quiet Zone width is 1 inch.
Bar Code, Expanded Character Unit, Line Block Drawing & Box
Drawing
n = “u0” or “U0” Millimeters (default)
n = “u1” or “U1” 1/10”
n = “u2” or “U2” 1/100”
n = “u3” or “U3” 1/12”
n = “u4” or “U4” 1/120”
n = “u5” or “U5” 1/10 Millimeters
n = “u6” or “U6” 1/300”
n = “u7” or “U7” 1/720”
This parameter specifies the measurement units of X-axis offset, Y-axis