3-23
Cisco ONS 15454 Reference Manual, R7.0
78-17191-01
Chapter 3 Electrical Cards
3.8 3.8.3 DS3-12E and DS3N-12E Card-Level Indicators
Figure 3-10 DS3N-12E Faceplate and Block Diagram
3.8.3 DS3-12E and DS3N-12E Card-Level Indicators
Table 3-11 describes the three card-level LEDs on the DS3-12E and DS3N-12E card faceplates.
61350
B
a
c
k
p
l
a
n
e
DS3
ASIC
Flash
uP bus
SDRAM
BTC
ASIC
Line
Interface
Unit #1
main DS3-m1
protect DS3-p1
Line
Interface
Unit #1
main DS3-m12
protect DS3-p12
Processor
OHP
FPGA
BERT
FPGA
FAIL
ACT/STBY
SF
DS3 N
12E
Table 3-11 DS3-12E and DS3N-12E Card-Level Indicators
Card-Level Indicators Description
Red FAIL LED The red FAIL LED indicates that the card processor is not ready. Replace the
card if the red FAIL LED persists.
ACT/STBY LED
Green (Active)
Amber (Standby)
When the ACT/STBY LED is green, the card is operational and ready to
carry traffic. When the ACT/STBY LED is amber, the card is operational and
in standby (protect) mode.
Amber SF LED The amber SF LED indicates a signal failure or condition such as port LOS
or AIS.