Cisco Systems SCE 2000 4xGBE Network Card User Manual


 
Chapter 8 Troubleshooting
Problem Solving Using a Subsystems Approach
Cisco SCE 2000 4xGBE Installation and Configuration Guide
OL-7824-04 8-9
When all LEDs come on to indicate that the system has booted successfully, the initial
system banner should be displayed on the console screen. If it is not displayed, see
Connecting the Local Console (on page 5-1) to verify that the terminal is set correctly and
that it is properly connected to the console port.
If the banner is displayed, but the Status LED is flashing orange, indicating a warning state,
check the user log:
At the prompt, type: more user log
If any of the following warning messages appear, turn the SCE 2000 platform off and call
technical support.
"voltage problem:"
"fans problem"
"abnormal raise in interior temperature:"
If the following warning message appears, delete unneeded files from the disk.
“insufficient disk space:”
Troubleshooting the Power Subsystem
Check the following to help isolate a problem in the power subsystem. In the normally configured
SCE 2000 platform with redundant power supply units, it is unlikely that the device will not start
at all. However, at startup it should be verified that both power supply units are operational, and
therefore the following steps should be followed if one of the Power LEDs on the front panel
remains unlit when the SCE 2000 platform is powered up.
Note
If the system powers off due to an environmental shutdown, wait at least one minute before manually
rebooting the system, or it will pause indefinitely.