Cisco Systems N5KC5596TFA Switch User Manual


 
20 Po20 up failed Global compat check failed 1-10
30 Po30 up failed Global compat check failed 1-10
Viewing An Interface-Specific Type-1 Inconsistency
When an interface-specific Type-1 inconsistency occurs, the vPC port on the secondary switch is brought
down while the primary switch vPC ports remain up.The following example shows this type of inconsistency
when there is a switchport mode mismatch.
This example shows how to display the status of the suspended vPC VLAN on the secondary switch:
switch(config-if)# show vpc brief
Legend:
(*) - local vPC is down, forwarding via vPC peer-link
vPC domain id : 10
Peer status : peer adjacency formed ok
vPC keep-alive status : peer is alive
Configuration consistency status: success
Per-vlan consistency status : success
Type-2 consistency status : success
vPC role : secondary
Number of vPCs configured : 2
Peer Gateway : Disabled
Dual-active excluded VLANs : -
Graceful Consistency Check : Enabled
vPC Peer-link status
---------------------------------------------------------------------
id Port Status Active vlans
-- ---- ------ --------------------------------------------------
1 Po1 up 1
vPC status
----------------------------------------------------------------------------
id Port Status Consistency Reason Active vlans
------ ----------- ------ ----------- -------------------------- -----------
20 Po20 up success success 1
30 Po30 down* failed Compatibility check failed -
for port mode
This example shows how to display the inconsistent status ( the VLANs on the primary vPC are not suspended)
on the primary switch:
switch(config-if)# show vpc brief
Legend:
(*) - local vPC is down, forwarding via vPC peer-link
vPC domain id : 10
Peer status : peer adjacency formed ok
vPC keep-alive status : peer is alive
Configuration consistency status: success
Per-vlan consistency status : success
Type-2 consistency status : success
vPC role : primary
Number of vPCs configured : 2
Peer Gateway : Disabled
Dual-active excluded VLANs : -
Graceful Consistency Check : Enabled
vPC Peer-link status
---------------------------------------------------------------------
id Port Status Active vlans
-- ---- ------ --------------------------------------------------
1 Po1 up 1
vPC status
Cisco Nexus 5000 Series NX-OS Interfaces Configuration Guide, Release 5.2(1)N1(1)
98 78-26881-OL
Configuring Virtual Port Channels
Viewing An Interface-Specific Type-1 Inconsistency