Cisco Systems N5KC5596TFA Switch User Manual


 
You must ensure that the two switches connected by the vPC peer link have certain identical operational
and configuration parameters.
Note
When you configure the vPC peer link, the vPC peer switches negotiate that one of the connected switches
is the primary switch and the other connected switch is the secondary switch. By default, the Cisco NX-OS
software uses the lowest MAC address to elect the primary switch. The software takes different actions on
each switch—that is, the primary and secondary—only in certain failover conditions. If the primary switch
fails, the secondary switch becomes the operational primary switch when the system recovers, and the previously
primary switch is now the secondary switch.
You can also configure which of the vPC switches is the primary switch. If you want to configure the role
priority again to make one vPC switch the primary switch, configure the role priority on both the primary and
secondary vPC switches with the appropriate values, shut down the EtherChannel that is the vPC peer link
on both switches by entering the shutdown command, and reenable the EtherChannel on both switches by
entering the no shutdown command.
MAC addresses that are learned over vPC links are also synchronized between the peers.
Configuration information flows across the vPC peer links using the Cisco Fabric Services over Ethernet
(CFSoE) protocol. All MAC addresses for those VLANs configured on both switches are synchronized
between vPC peer switches. The software uses CFSoE for this synchronization.
If the vPC peer link fails, the software checks the status of the remote vPC peer switch using the peer-keepalive
link, which is a link between vPC peer switches, to ensure that both switches are up. If the vPC peer switch
is up, the secondary vPC switch disables all vPC ports on its switch. The data then forwards down the remaining
active links of the EtherChannel.
The software learns of a vPC peer switch failure when the keepalive messages are not returned over the
peer-keepalive link.
Use a separate link (vPC peer-keepalive link) to send configurable keepalive messages between the vPC peer
switches. The keepalive messages on the vPC peer-keepalive link determines whether a failure is on the vPC
peer link only or on the vPC peer switch. The keepalive messages are used only when all the links in the peer
link fail.
vPC Number
Once you have created the vPC domain ID and the vPC peer link, you can create EtherChannels to attach the
downstream switch to each vPC peer switch. That is, you create one single EtherChannel on the downstream
switch with half of the ports to the primary vPC peer switch and the other half of the ports to the secondary
peer switch.
On each vPC peer switch, you assign the same vPC number to the EtherChannel that connects to the downstream
switch. You will experience minimal traffic disruption when you are creating vPCs. To simplify the
configuration, you can assign the vPC ID number for each EtherChannel to be the same as the EtherChannel
itself (that is, vPC ID 10 for EtherChannel 10).
The vPC number that you assign to the EtherChannel connecting to the downstream switch from the vPC
peer switch must be identical on both vPC peer switches.
Note
Cisco Nexus 5000 Series NX-OS Interfaces Configuration Guide, Release 5.2(1)N1(1)
78-26881-OL 75
Configuring Virtual Port Channels
vPC Number