Cisco Systems OL-19806-03 Switch User Manual


 
1-6
Cisco EnergyWise Configuration Guide
OL-19806-03
Chapter 1 Managing Single Entities
Attributes
Attributes
Recurring Event
You can configure the switch to power an end point or interface on and off based on the time or date.
A recurring event, also referred to as a recurrence, uses the switch time.
The settings are only in the running configuration.
If the switch fails and then restarts, it uses the power level in the saved configuration.
Secure Domain Communication
Configure the security mode and password, referred to as the shared secret, to prevent replay attacks.
You set either a strong password with Network Time Protocol (NTP) or a strong password without NTP.
When you use NTP to synchronize the time among domain members and you set a shared secret with
NTP, EnergyWise uses the current time with the shared secret to enhance prevention of replay attacks.
Ta b l e 1-2 Keywords, Name, and Role
Definition Defaults
Keywords Device description (other than
the name or role) for which
query results are filtered
None.
Name Device identity for which query
results are filtered
For a PoE port, the short version of the port name. For
example, Gi0.2 for Gigabit Ethernet
0/2.
For a switch, the hostname.
For an end point, see the documentation for the end
point and the agent or client running on it. We
recommend that you use the hostname.
Role Device function based on the
business or deployment context
For a PoE port, the default is interface.
For a switch, the default can be the model number or
the supervisor model number.
For an end point, see the documentation for the end
point and the agent or client running on it.