Cisco Systems OL-19806-03 Switch User Manual


 
3-24
Cisco EnergyWise Configuration Guide
OL-19806-03
Chapter 3 EnergyWise CLI Commands
show energywise
Switch# show energywise level delta
Levels (Watts)
Interface Name 0 1 2 3 4 5 6 7 8 9 10
--------- ---- ------------------------------------------------------------------------
lobby.1 -130.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
Switch# show energywise level delta child
Levels (Watts)
Interface Name 0 1 2 3 4 5 6 7 8 9 10
--------- ---- ------------------------------------------------------------------------
lobby.1 -558.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
Gi0/1 Gi0.1 0.0 15.4 15.4 15.4 15.4 15.4 15.4 15.4 15.4 15.4 15.4
Gi0/2 LWAPP-AP-1 -9.91 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
Gi0/3 Gi0.3 0.0 15.4 15.4 15.4 15.4 15.4 15.4 15.4 15.4 15.4 15.4
<output truncated>
Switch# show energywise neighbors
Capability Codes: R - Router, T - Trans Bridge, B - Source Route Bridge
S - Switch, H - Host, I - IGMP, r - Repeater, P - Phone, U - Unknown
Id Neighbor Name Ip:Port Prot Capability
-- ------------- ------- ---- ----------
1 Router A 10.0.0.11:43440 udp R
2 Switch A 10.0.0.12:43440 cdp S I
3 Router B 10.0.0.36:43440 cdp U
4 IP_phone A 10.0.0.14:43440 udp U
5 Switch B 10.0.0.4:43440 udp R
6 Switch C 10.0.0.5:43440 udp R
7 Router C 10.0.0.7:43440 udp R
When you use the energywise level level recurrence importance importance {at minute hour
day_of_month month day_of_week global configuration command
Switch# show energywise recurrences
Id Addr Class Action Lvl Cron//Time-range
-- ---- ----- ------ --- ---------------
2 Gi0/17 QUERY SET 3 minutes: 0 hour: 8 day: * month: * weekday: *
3 Gi0/18 QUERY SET 3 minutes: 0 hour: 8 day: * month: * weekday: *
4 Gi0/19 QUERY SET 3 minutes: 0 hour: 8 day: * month: * weekday: *
When you use the energywise level level recurrence importance importance time-range
time-range-name global configuration command
Switch# show energywise recurrences
Id Addr Class Action Lvl Cron/Time-range
-- ---- ----- ------ --- ---------------
1 Gi0/1 QUERY SET 10 tt-range
Switch# show energywise statistics
Children: 48 Errors: 0 Drops: 31 Events: 643
Switch# show energywise usage
Interface Name Usage Caliber
--------- ---- _____ _______
lobby.1 130.0 (W) max