Cisco Systems OL-19806-03 Switch User Manual


 
3-9
Cisco EnergyWise Configuration Guide
OL-19806-03
Chapter 3 EnergyWise CLI Commands
energywise (interface configuration)
keywords word,word (Optional) Assigns at least one keyword for the port.
When assigning multiple keywords, separate the keywords with commas,
and do not use spaces between keywords.
You can enter alphanumeric characters and symbols such as #, (, $, !, and
&.
Do not enter an asterisk (*) or a blank space between the characters or
symbols.
level level (Optional) Sets the power level of the port.
The range is from 0 and 10.
To power off the end point, enter 0.
To power on the end point
If it is a PoE end point, enter 10.
If it is not, enter a power level from 1 to 10. The end point
determines the appropriate action.
recurrence
importance importance
{at minute hour
day_of_month month
day_of_week |
time-range
time-range-name}
(Optional) Schedules the power-on or power-off event.
importance importance—The event occurs if the importance value of
the end point is less than or equal to the specified importance value. The
range is from 1 to 100.
at minute hour day_of_month month day_of_week—Specifies the time
(24-hour format) in cron format for the recurring event.
minute—The range is from 0 to 59. Use * for the wildcard.
hour—The range is from 0 to 23. Use * for the wildcard.
day_of_month—The range is from 1 to 31. Use * for the wildcard.
month—The range is from 1 (January) to 12 (December). Use * for
the wildcard.
day_of_week—The range is from 0 (Sunday) to 7 (Sunday). Use *
for the wildcard.
time-range time-range-name—Specifies the time range name for the
recurring event.
The event uses the switch time.
name name (Optional) Specifies the EnergyWise-specific port name.
You can enter alphanumeric characters and symbols such as #, (, %, !,
and &.
Do not enter an asterisk (*) or a blank space between the characters or
symbols.