Fault Messages
203
HMR BANK FAN FLT Yes Sensors cannot detect
current in fan circuit.
Check that fan cable is
connected. Check for obstruction
of vents and fan airway; remove
any obstructions. Check for items
beneath the printer blocking
cabinet vents. Power back on the
printer. If this message recurs,
contact your authorized service
representative.
1
HB NOT INSTALLD* No Self-test does not detect
hammer coils.
Contact your authorized service
representative.
1
ILL EXT BUS ACC* No Fatal firmware error on
controller board.
Contact your authorized service
representative.
1
ILLGL OPR ACCSS* No Fatal firmware error on
controller board.
Contact your authorized service
representative.
1
ILL INST ACCSS* No Fatal firmware error on
controller board.
Contact your authorized service
representative.
1
INTAKE FAN FAULT Yes Sensors cannot detect
current in fan circuit.
See description for
HMR BANK FAN FLT.
LO DRV. SHORT * No Circuit(s) on the hammer
bank or in the hammer bank
power cable shorted to
ground.
Contact your authorized service
representative.
1
LOAD PAPER Yes Printer is out of paper. Load paper.
ONLINE
8344 FAILED*
No Link-level code test detects
hardware failure.
Contact your authorized service
representative.
1
PAP BAD TABLE* No Fatal firmware error on
controller board.
Contact your authorized service
representative.
1
PAP BSY TOO LNG* No Fatal firmware error on
controller board.
Contact authorized service
representative.
1
PAP FIFO OVERFL* No Fatal firmware error on
controller board.
Contact your authorized service
representative.
1
PAP FIFO UNDRFL* No Fatal firmware error on
controller board.
Contact your authorized service
representative.
1
Table 15. LCD Message Troubleshooting Table (continued)