Crestron electronic TPS-GA-TPI Computer Monitor User Manual


 
Crestron TPS-GA-TPI Isys
®
G-Series Touchpanel Interface
Operations Guide – DOC. 6501 Isys
®
G-Series Touchpanel Interface: TPS-GA-TPI 29
Diagnostics Menu
The Diagnostics button from the MAIN MENU contains controls for diagnostic
tools. The diagnostic tools should only be used under supervision from a Crestron
customer service representative during telephone support. The options available from
the DIAGNOSTICS MENU are numeric in nature and their interpretation is beyond
the scope of this manual.
DIAGNOSTICS MENU
Installation
Ventilation
The TPS-GA-TPI should be used in a well-ventilated area. The venting holes should
not be obstructed under any circumstances. If the TPS-GA-TPI is hot to the touch,
consider using forced air ventilation and/or incrementing the spacing between units.
To prevent overheating, do not operate this product in an area that exceeds the
environmental temperature range listed in the table of specifications. Consideration
must be given if installed in a closed or multi-unit rack assembly since the operating
ambient temperature of the rack environment may be greater than the room ambient
temperature. Contact with thermal insulating materials should be avoided on all sides
of the unit.
Rack Mounting
The TPS-GA-TPI can be mounted in a rack or stacked with other equipment. Two
“ears” are provided with the TPS-GA-TPI so that the unit can be rack mounted.
These ears must be installed prior to mounting. Complete the following procedure to
attach the ears to the unit. The only tool required is a #2 Phillips screwdriver.
WARNING: To prevent bodily injury when mounting or servicing this unit in a
rack, take special precautions to ensure that the system remains stable. The following
guidelines are provided to ensure your safety:
When mounting this unit in a partially filled rack, load the rack from the
bottom to the top with the heaviest component at the bottom of the rack.