Crestron electronic TPS-GA-TPI Computer Monitor User Manual


 
Crestron TPS-GA-TPI Isys
®
G-Series Touchpanel Interface
Operations Guide – DOC. 6501 Isys
®
G-Series Touchpanel Interface: TPS-GA-TPI 5
TPS-GA-TPI Specifications (Continued)
SPECIFICATION DETAILS
Power Requirements
3
Power Supply
(sold separately)
PW-2420RU
Cresnet Power Usage
45 Watts
(1.875 Amps @ 24 Volts DC)
Default NET ID 03
Minimum 2-Series Control
System Update File
4, 5, 6
Version 3.155.1143
or later
Environmental
Temperature 50° to 113°F (10° to 45°C)
Humidity 10% to 90% RH (non-condensing)
Enclosure
Construction
Black metal, 1U 19-inch rack-mountable
(rack ears included)
Dimensions
Height
1.80 in (4.57 cm) with feet,
1.70 in (4.32 cm) without feet
Width
19.0 in (48.26 cm) with ears,
17.03 in (43.24 cm) without ears
Depth 10.68 in (27.13 cm)
Weight 4.8 lbs (2.2 kg)
Available Accessories
PW-2420RU Power Supply
ST-PK Programming Cable Kit
1. Specific models and protocols subject to verification; refer to the Crestron website or contact factory
for latest device support.
2. Depends on screen resolution.
3. Power should only be applied to the 24VDC power jack OR the NET port, not both.
4. The latest software versions can be obtained from the Crestron website. Refer to the NOTE following
these footnotes.
5. Crestron 2-Series control systems include the AV2 and PRO2. Consult the latest Crestron Product
Catalog for a complete list of 2-Series control systems.
6. When loading VisionTools (VT) Pro-e files or firmware through the RS-232 port of the control
system, be sure that the baud rate is at 38400 (Cresnet speed) or lower. Otherwise, Toolbox may post
the “Transfer Failed” message.
NOTE: Crestron software and any files on the website are for authorized Crestron
dealers and Crestron Authorized Independent Programmers (CAIP) only. New users
may be required to register to obtain access to certain areas of the site (including the
FTP site).