Dell 1955 Computer Hardware User Manual


 
38 About Your System
Memory address line
failure at
address
, read
value
expecting
value
Memory double word logic
failure at
address
, read
value
expecting
value
Memory odd/even logic
failure at
start address
to
end address
Memory write/read failure
at
address
, read
value
expecting
value
Faulty or improperly installed memory
modules, or faulty server module
board.
Ensure that all memory modules are
properly installed. See "Troubleshooting
Server Module Memory" on page 112. If
the problem persists, see "Getting Help"
on page 127.
Memory mirroring enabled Memory mirroring enabled Information only.
Memory tests terminated by
keystroke
The spacebar was pressed during
POST to terminate the memory test.
Information only.
No boot device available Faulty or missing diskette drive,
optical drive, or hard drive.
Check the Integrated Devices
configuration settings in the System
Setup program and ensure that the
controller for the boot device is enabled.
See "Using the System Setup Program"
on page 43. Ensure that the controller
for the boot device is enabled.
If the problem persists, replace the drive.
See "Hard Drives" on page 89.
No boot sector on
hard-disk drive
An operating system is not on the
hard drive.
Check the hard-drive configuration
settings in the System Setup program.
See "Using the System Setup Program"
on page 43.
No timer tick interrupt Faulty server module board. See "Getting Help" on page 127.
Not a boot diskette Not a bootable diskette. Use a bootable diskette.
PCI BIOS failed to install Faulty or improperly installed. Reseat the daughter card. See "I/O
Module Daughter Card" on page 82. If
the problem persists, see "Getting Help"
on page 127.
Table 1-13. Server Module Messages (continued)
Message Causes Corrective Actions