Dell 1955 Computer Hardware User Manual


 
74 Installing System Options
Installing a Server Module
NOTICE: Follow this procedure carefully—it is possible to insert the server module upside-down, which may
damage the chassis midplane and the server module.
1
Orient the server module so that its top side is up. The server module is correctly oriented for
installation when its components have the characteristics described below:
a
The server module’s upper handle is above (outside) the lower handle.
The upper handle has the DELL logo™ on it, extends farther out than the lower handle, and has a
release latch on its inside. See Figure 3-12.
b
The upper edge of the server module has "TOP-SIDE" engraved in it. See Figure 3-12.
Figure 3-12. Proper Server Module Installation Orientation
2
Slide the server module into the chassis until the open handles touch the front panel of the chassis.
3
Rotate both handles inward until the lower handle is flush against the server module’s front panel.
The lower handle automatically closes before the upper handle.
1 upper handle 2 "TOP-SIDE" engraved in server
module
3 server module
4 lower handle 5 logo 6 release latch inside of upper
handle
1
3
4
6
5
2