Dell 1955 Computer Hardware User Manual


 
40 About Your System
Warning Messages
A warning message alerts you to a possible problem and prompts you to respond before the system
continues a task. For example, before you format a diskette, a message will warn you that you may lose all
data on the diskette. Warning messages usually interrupt the task and require you to respond by typing
y
(yes) or
n (no).
NOTE: Warning messages are generated by either the application or the operating system. For more information,
see the documentation that accompanied the operating system or application.
Diagnostics Messages
When you run system diagnostics, an error message may result. Diagnostic error messages are not
covered in this section. Record the message on a copy of the Diagnostics Checklist in "Getting Help,"
then follow the instructions in that section for obtaining technical assistance.
Unsupported CPU
combination
Mismatched processors are installed.
Processor is not supported by the
server module.
Replace a microprocessor so that both
microprocessors match. See "Processors"
on page 84.
Check for a BIOS update using the Dell
Support website at support.dell.com.
Unsupported CPU stepping
detected
Processor is not supported by the
server module.
Check for a BIOS update using the Dell
Support website at support.dell.com. If
the problem persists, install a supported
processor. See "Processors" on page 84.
Warning! No microcode
update loaded for
processor
n
Unsupported processor. Update the BIOS firmware using the
Dell Support website at
support.dell.com.
Warning: The current
memory configuration is
not validated. Change it
to the recommended memory
configuration or press any
key to continue.
There is no memory configuration
error, but the memory configuration is
not recommended by Dell.
See "General Memory Module
Installation Guidelines" on page 78.
Write fault
Write fault on selected
drive
Faulty diskette, diskette drive, optical
drive, hard drive.
Replace the diskette. Ensure that the
custom cable is properly connected. See
"Troubleshooting USB Devices" on
page 105 or "Troubleshooting Hard
Drives" on page 113 for the appropriate
drive(s) installed in your system.
Table 1-13. Server Module Messages (continued)
Message Causes Corrective Actions