Digi 90031300 Network Router User Manual


 
T1 Modem Bank
60
The results of the POST sequence are displayed, and the T1 Modem Bank begins listening for a ping packet from the
EPC/X host adapter. While listening for a ping packet, the T1 Modem Bank cycles through various baud rates and
clocking modes as it tries to link up with the EPC/X host adapter. The following messages will scroll continuously
until you press ? to get the configuration/diagnostic menu:
Listening mode gpp=0x038 mode 15 2400b NRZ ext
...no packet
Listening mode gpp=0x038 mode 60 115kb NRZI clk/16
...no packet
Listening mode gpp=0x038 mode 61 115kb FM0 clk/16
...no packet
Listening mode gpp=0x038 mode 15 2400b NRZ ext
...no packet
Listening mode gpp=0x038 mode 62 230kb NRZI clk/16
...no packet
Listening mode gpp=0x038 mode 63 230kb FM0 clk/16
...no packet
Listening mode gpp=0x038 mode 15 2400b NRZ ext
...no packet
Listening mode gpp=0x038 mode 64 460kb NRZI clk/16
...no packet
Listening mode gpp=0x038 mode 65 460kb FM0 clk/16
...no packet
Listening mode gpp=0x038 mode 15 2400b NRZ ext
...no packet
Listening mode gpp=0x038 mode 66 921kb NRZI clk/16
...no packet
Listening mode gpp=0x038 mode 67 921kb FM0 clk/16
...no packet
Listening mode gpp=0x038 mode 15 2400b NRZ ext
...no packet
Listening mode gpp=0x038 mode 68 1843kb NRZI clk/8
...no packet
Listening mode gpp=0x038 mode 69 1843kb FM0 clk/8
...no packet
Press ? to see the configuration/diagnostic menu:
---DIAGNOSTIC MENU---
A = All tests (except 9)
1 = Front Panel light test
2 = RAM test
3 = Timer test
4 = Line Card test
5 = Modems test
6 = Sync internal loopback test
7 = Sync external loopback test
8 = EEPROM test
9 = Watchdog test
N = Set concentrator number (currently 1)
L = Line Card configuration
B = Reboot concentrator
d^DD)ump, r^RR)ead, w^WW)rite, f^FF)ill RAM