Dynalink RTA1046VW Network Router User Manual


 
Wireless IAD User Manual
136
Therefore, when the log level is
“Debugging” and the display level is
“Error”, the CPE logs the most
detailed message but shows error
level data only.
Mode:
You can choose where to store the
logs; the options include Local,
Remote and Both. Local means the
CPE, i.e., the wireless IAD. Remote
means the log server you specified to
forward the log information to. The
default mode is Local.
If you choose Remote or Both, you
have to specify the Server IP
Address and UDP Port, and all the
events will be sent to the specified
UDP port of the specified log server.
Note:
Display Level only filters for the local
side. All the messages will be
displayed on the remote Log Server.
Example
Suppose we are going to record the system logs on both the wireless IAD and the
Server bearing IP address 10.11.95.2, the procedures below illustrate the situation:
System Log Configuration
1. Choose Enabled Log.
2. Select Debugging as the Log
Level, and Error as the Display
Level. (Or select other level
according to your needs.)
3. Set the Mode as Both, key in the
Server IP Address as 10.11.95.2,
and leave the Server UDP Port
as the default value 514.
4. Press Apply to invoke the
settings.