Enterasys Networks 7H4385-49 Computer Hardware User Manual


 
Overview of DFE Module Shutdown Procedure
DFE-Platinum Series Hardware Installation Guide 4-9
Figure 4-2 OFFLINE/RESET Switch
Recommended Shutdown Procedure Using OFFLINE/RESET
Switch
BeforepullingaDFEmoduleoutofachassis,
pressortaponitsOFFLINE/RESETswitchforlessthan1 second.
ItsCPULEDchangesfromsolidgreentoblinkingbetweengreenandamber,indicating
thattheDFEmoduleisshuttingdown.AttheendoftheDFEmoduleshutdownroutine,
the
CPULEDchangestoa67%/33%sequenceofamber/off,respectively,indicatingthe
moduleisinahaltstate.InthistimeitissafetorestartorremovetheDFEmodulefrom
thechassis.
WhenacontrolledshutdownisinitiatedfromtheOFFLINE/RESETswitch,youhave60
secondsfromthetime
theCPUstartsflashingamber/offuntiltheti me thedeviceis
automaticallyrestarted.
1 OFFLINE/RESET switch (in similar location on all DFE modules)
À
CPU
POE
1X
G
R
O
U
P
1
OFFLINE/
RESET
COM
MGMT
GROUP
SELECT
GROUP
1
2
3
4
5
6
1
2
3
4
7H4385-49
FAST ENET
Caution: Do not pull any DFE module out of an operating chassis before it has completed
its shutdown routine.
Precaución: No retire los módulos DFE del chasis en funcionamiento hasta que no se
haya terminado con la rutina de apagado.
Note: The only safe time to pull a DFE module out of the chassis is when the CPU LED is