![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/6/da/6dae3b9c-04c0-47c6-ba12-677edf2d496d/6dae3b9c-04c0-47c6-ba12-677edf2d496d-bg19.png)
Configuration Selections
NOTES: • In a typical installation, you:
• Must change the address (2 or 12), netmask (3 or 13), gateway address
(4 or 14), and controller IP (7).
• May need to change the boot method (1 or 11).
• Most installers do not need to change the other selections. If you do change
settings, note the existing values before the change in case you need to
change back.
• Options 0 through 6 are the settings for LAN port 1 (the RJ-45 port).
• Options 10 through 16 are the settings for LAN port 3 (the optical port).
• Options 7 through 9, 17, and 18 are controller related.
• Selections marked with an asterisk (*) in options 0 and 10 below are the
default VNC 325 hardware settings and the correct selection in most cases.
Table 5. Configuration Selections
LAN Port Specific Options
Option Function Comments
0 Speed/Duplex:
LAN port 1 link speed
Allows you to set the speed of the RJ-45 LAN port manually
using the following subselections:
* 1. auto_10_100_1000
2. auto_10_100
3. fixed_1000F
4. fixed_100F
5. fixed_100H
10 Speed/Duplex:
LAN port 2 link speed
Allows you to set the speed of the optical LAN port manually
using the following subselections:
6. fibre_auto_1000
* 7. fibre_fixed_1000F
1 and 11 Boot method:
Set static or dhcp
Entering 1 (11) toggles this option. When DHCP is selected
items 2 (12) through 5 (15) are not accessible.
NOTE: Extron recommends that you use static IP addresses.
2 and 12 address:
Set the local address
of the LAN port
• Standard Ethernet IP addressing rules apply.
• Manually enter the IP address for the port; use no leading
zeroes. For example: 192.168.0.1 is valid, 192.168.000.001
is not valid.
3 and 13 netmask:
Set the appropriate
subnet mask for the
network.
• Standard Ethernet subnet rules apply.
• Manually enter the IP address for the port; use no leading
zeroes. For example: 255.255.10.0 is valid, 255.255.010.0
is not valid.
VN-Matrix 325 Serial Digital Over IP CODEC • Installation and Setup 19