Extron electronic 325 Switch User Manual


 
Firmware Upgrade Page
Extron may occasionally issue firmware upgrades for the VNC 325. See the Extron website,
www.extron.com, for details of the latest firmware release. Upgrades are supplied in a
single file, “upgrade_verx.x.tar”, where verx.x is the version number. Copy the upgrade
file onto the computer that you use to access the VNC 325 unit that is designated as the
controller.
Firmware upgrade is a multi-stage process, highlighted in table 10 and figure 42. The
detailed procedure begins on the next page. Extron recommends that all VNC 325 units in
the system be upgraded to the same firmware version to ensure full compatibility.
Table 10. Firmware Upgrade Stages
Stage Function Summary Perform on
Upload Copy the upgrade file from the control PC to a temporary
storage area on the controller.
The controller
VNC 325 only
Prepare Unpack and copy the upgrade into all units. All VNC 325s
Activate Activate the upgrade in temporary mode. It can be abandoned
if problems occur.
All VNC 325s
Commit Permanently commit to the upgrade. All VNC 325s
Upload
Device Upgrade Status:
WAIT
Prepare Activate
WAIT
Automatic
Reboot
Automatic
Reboot
Commit
Loaded Installed but idle
Test New Firware
Existing firmware
Upgraded firmware
OperatingOperating temporarilly
Figure 42. Temporarily Installing, Testing, and Permanently Installing New Software
The process allows you to temporarily install and test the new firmware and, if everything is
OK, you can then permanently install (commit) the new firmware. Up until the last stage it is
possible to return to the existing firmware version.
VN-Matrix 325 Serial Digital Over IP CODEC • Operation 53