Extron electronic 325 Switch User Manual


 
Configuring a Serial Pass-through Group
NOTE: The client and server ends of the serial pass-through connection do not have
to have the same baud rate settings, however having the different ends at
vastly different rates can result in unexpected results.
1. Decide which device is to be the server.
2. On the device list page (see figure 23 on page 32), click on the device you want to
configure.
3. On the device page (see figure 25 on page 34), click the peripherals tab.
4. On the peripherals page (see
a
on figure 41), set the mode to either server or
client.
If you select client, the destination drop-down box (
c
) appears.
1
Configuring the Server Configuring a Client
14 4
2 2
2 2
2 2
2 2
2 2
3
Figure 41. Configuring a Serial Pass-through Group
5. Configure the baud rate, data bits, stop bits, parity, and handshake settings as required
(
b
).
6. In the destination drop-down box, select passthrough for the appropriate server (
c
).
7. Click the update button (
d
).
8. Repeat steps 2 through 7 for all
9. Click the Save All tab to save the changes.
NOTE: If you do not click Save All, the settings are lost when power is cycled on
and off.
VN-Matrix 325 Serial Digital Over IP CODEC • Operation 52