Extron electronic DXP DVI Pro Network Router User Manual


 
DXP DVI Pro and DXP HDMI Series • Operation 32
Saving and Recalling Presets
The current configuration (0) can be saved as a preset in any one of 32 preset memory
addresses. Preset locations are assigned to the input buttons and (where necessary) output
buttons. Up to 32 presets can be selected from the front panel to be either saved or
retrieved. When a preset is retrieved from memory, it becomes the current configuration.
NOTES: Presets cannot be viewed from the front panel unless recalled as the current
configuration. Presets can be viewed using the Matrix Switchers Control
program (see the “Matrix Software” section, starting on page 70, for
more details).
The current configuration and all presets are stored in non-volatile memory.
When power is removed and restored, the current conguration is still active
and all presets are retained.
When a preset is recalled, it replaces the current conguration, which is lost
unless it is also stored as a preset. The recalled preset overwrites all of the
current configuration ties in favor of the preset ties.
All models have 32 presets; however, only up to 16 presets (the number of
front panel buttons) can be selected from the front panel. Preset numbers
greater than 16 can be accessed under serial port or Ethernet control.
Preset
1
Preset
5
Preset
2
Preset
3
Preset
8
Preset
6
Preset
7
Preset
4
Preset
9
Preset
13
Preset
10
Preset
11
Preset
16
Preset
14
Preset
15
Preset
12
INPUTS
1
2
3
4
5
6
7
8
1
2
3 4
5
6
7
8
OUTPUTS
NOTE: Presets 17 through 32 are available via
RS-232/RS-422 and Ethernet control only.
Figure 44. Preset Locations for All DXP Models
Example 6: Saving a Preset
In the following example, the current configuration is saved as a preset. The steps show
the front panel indications that result from your action.
1. Press and release the Esc button.
C O N T R O L
PRESET
ENTER
ESCVIEW
Press the Esc button to clear all selections.
The button flashes once.
Figure 45. Clear All Selections