Extron electronic DXP DVI Pro Network Router User Manual


 
DXP DVI Pro and DXP HDMI Series • SIS Configuration and Control 52
SIS Commands for DXP
Symbol Definitions for DXP
]
= Carriage return and line feed
}
= Carriage return (no line feed)
= Space
E
= Escape key
NOTE: Input and output numbers in commands may be entered as either one-digit, two-
digit, or three-digit numbers. All input and output numbers are reported as two-digit
numbers in the response.
X!
= Input number 1 – maximum number of inputs for your model
X@
= Input number (for ties)
0 – maximum number of inputs for your model
(0 = untied)
X#
= Output number 1 – maximum number of outputs for your model
X$
= Lock mode, power, 0 = lock mode 0, not OK, or unmuted
supply or individual 1 = lock mode 1, OK, or muted
mute status 2 = lock mode 2
X%
= Group number (for I/O 1 through 4 groups
grouping) 0 = no group
X^
= Room number (for room 10 maximum. Each room can have up to 10 room
presets) presets (
X*) assigned.
NOTE: A room is a subset of operator-selected outputs that relate to each other. The DXP
switchers support up to 10 rooms, each of which can consist of from 1 to 16 outputs.
X&
= Global preset number 0032 (00 = current configuration)
X*
= Room preset number 00 – current ties for the room in view mode, 10
maximum
NOTE: A room preset is a stored configuration with all of the outputs assigned to a single
room. When a room preset is retrieved from memory, it becomes the current
configuration.
X(
= All video and audio mute 0 = no mutes
status 1 = video mute
2 = audio mute
3 = video and audio mute
X1)
= HDCP status 0 = no input or output connected
1 = input or output connected and not HDCP
compliant
2 = input or output connected and HDCP compliant
X1!
= Connection status 0 = no input connected
1 = input connected
X1#
= Name 12 characters maximum for input, output, and global
preset names
11 characters maximum for room names
Upper- and lowercase alphanumeric characters are
valid.
NOTE: The following characters are invalid or not recommended in the name:
{space} ~ , @ = ‘ [ ] { } < > ‘ ’ “ ” ; : | \ and ?.
X1$
= Total inputs Total number of inputs for this switcher
X1%
= Total outputs Total number of outputs for this switcher
X1^
= Voltage Positive or negative voltage and magnitude
X1&
= Temperature Degrees Fahrenheit
X1*
= Fan speed In RPM