Extron electronic DXP DVI Pro Network Router User Manual


 
DXP DVI Pro and DXP HDMI Series • SIS Configuration and Control 57
Command
ASCII Command
(Host to Switcher)
Response
(Switcher to Host)
Additional Description
Save, Recall, and Directly Write Global and Room Presets (continued)
Directly write a
global preset
E
+
X&
P
X@
*
X#
!
X@
*
X#
%
X@
*
X#
$...
X@
*
X#
&
}
The tie all (!), tie RGB (&),
tie video (%), and tie audio ($)
commands are all valid.
Spr
X&]
Example:
+27P1*5!5*2$3*6%3*8&
Esc
Spr27
]
Brackets are shown to separate
ties for clarity only. Create
global preset 27, which ties
video and audio Input 1 to
Output 5, audio Input 5 to
Output 2, video Input 3 to
Output 6, and video Input 3 to
Output 8.
NOTE: The direct write of a global preset should always be preceded by a clear global preset ties command of that
same preset number, as shown below. In a directly-written preset, the tied input for each output position (or no
tied input) remains unchanged unless overwritten or cleared.
If you do not clear the ties in a global preset number before you directly write a global preset to that number,
ties that are part of the previous version of the specified preset with the same number can become part of the
newly-created preset.
Clear a global preset
E
+
X&
PO*!
}
Spr
X&]
Clear all ties in preset
X&
.
Example:
E
+ 27P0*!
}
Spr27
]
Clear all ties in preset 27.
Write room outputs
EX^
,
X#
1
,
X#
2
,...
X#
n
MR
}
Mpr
X^
,
X#
1
,
X#
2
,...
X#
n
]
Assign outputs to room
X^
.
See the notes below.
NOTES: A room can contain a maximum of 16 outputs.
An output can belong to only one room.
The maximum number of rooms (
X^
) is 10.
If no room name is assigned (see the Names commands on page 61), the default name is
Room #
X^
X#
1
,
X#
2
,
X#
3
.
Example:
E
8,3,4,5,6MR
}
Mpr8,3,4,5,6
]
Outputs 3, 4, 5, and 6 are
assigned to room 8.
Read room outputs
EX^
MR
}
X1#X^
,
X#
1
,
X#
2
,...
X#
n
]
Display the outputs assigned
to room
X^
.
Example:
E
3MR
}
Class1,1,2,6,8
]
Outputs 1, 2, 6, and 8 are
assigned to room 3, which is
named “Class 1.”
Recall room preset
X^
*
X*
.
Rmm
X^
Rpr
X*]
Command character is a
period.
NOTE:
X@
= Input number (for ties) 0 – maximum number of inputs for your model
X#
= Output number 1 – maximum number of outputs for your model
X^
= Room number (for room presets) Each room can have up to 10 presets (
X*
) assigned.
X&
= Global preset number 0032. 00 = current preset
X*
= Room preset number 00 – current ties for the room in view mode, 10 maximum
X1#
= Room name 11 characters maximum for room names. Upper- and lowercase
letters are valid.
NOTE: The following characters are invalid or not recommended in the name:
{space} ~ , @ = ` [ ] { } < > ‘ ’ “ ” ; : | \ and ?