Extron electronic MVX 128 Switch User Manual


 
Operation, cont’d
MVX 128 A VGA Matrix Switchers • Operation
3-22
PRELIMINARY
2. Press and hold the Preset button for approximately 2 seconds until the Preset
LED blinks (fi gure 3-34).
PRESET PRESET
1 2 3 4
Press and hold the Preset button until the
Preset LED blinks.
Release the
Preset button.
2 seconds
All input and output LEDs with assigned presets light.
If you then save the configuration to a lit preset number,
the configuration data at that preset location will be overwritten.
Lit
(Preset Assigned)
Output
LEDs
Unlit
(Preset Unassigned)
= Blinking LED
Preset 13 Preset 14 Preset 16Preset 15
Figure 3-34 — Enter Save Preset mode
3. Press and release the Output 1 button (fi gure 3-35).
ENTER PRESET VIEW
CONTROL
1 2 3 4
The Enter LED blinks to indicate
the need to save the preset.
The Preset LED continues to blink.
Press and release the Output 1 button.
The LED blinks to indicate that this preset
number is selected but not saved.
= Blinking LED
Preset 13 Preset 14 Preset 16Preset 15
Figure 3-35 — Select the preset
4. Press and release the Enter button (fi gure 3-36). The current confi guration is
now stored in memory location 13.
ENTER PRESET VIEW ESC
CONTROL
The Enter and Preset LEDs
return to the unlit state.
Press the Enter button to
save the preset.
All input LEDs
return to the
unlit state.
Figure 3-36 — Press the Enter button