Extron electronic PVS 305SA Switch User Manual


 
4-7
PVS 305SA • Serial Communication
PRELIMINARY
PRELIMINARY
Command ASCII command
(host to processor)
Response
(processor to host)
Additional description
Set a specific input’s
attenuation (-dB)
X!
*
X*
g In
X!
Aud
X(]
Set a specific input’s
attenuation.
Increment a specific input’s
attenuation
X!
*+g In
X!
Aud
X(]
Increase input attenuation.
Decrement a specific input’s
attenuation
X!
*-g In
X!
Aud
X(]
Decrease input attenuation.
View a specific input’s
attenuation
X!
*g In
X!
Aud
X(]
View specific input attenuation.
Set current input’s attenuation
(-dB)
X*
g In
X!
Aud
X(]
Set a specific input’s
attenuation.
Increment current input’s
attenuation
+g
In
X!
Aud
X(]
Increase input attenuation.
Decrement current input’s
attenuation
-g
In
X!
Aud
X(]
Decrease input attenuation.
View current input’s
attenuation
g
In
X!
Aud
X(]
View specific input attenuation.
Volume adjustment
Specify volume/variable
X^V
Vol
X^]
Set a specific volume.
Increment volume
+V
Vol
X^]
Increase value.
Decrement volume
-V
Vol
X^]
Decrease value.
View value
V
Vol
X^]
Show volume.
Bass adjustment
Specify bass level
X$<
Bas=
X%]
Set a specific bass level.
Increment bass level
+<
Bas=
X%]
Increase value.
Decrement bass level
-<
Bas=
X%]
Decrease value.
View bass level
<
Bas=
X%]
Show bass level.
Treble adjustment
Specify treble level
X$>
Trb=
X%]
Set a specific treble level.
Increment treble level
+>
Trb=
X%]
Increase value.
Decrement treble level
->
Trb=
X%]
Decrease value.
View treble level
>
Trb=
X%]
Show treble level.
N
Treble and bass are strictly global commands. They only adjust the TP inputs, captive screw audio input, and
VoiceLift receiver aux program audio signals. They do not adjust the VoiceLift receiver microphone audio signal.
Front panel lockout mode
Lock
1X
Exe
X#]
Lock out front panel.
Unlock
0X
Exe
X#]
Unlock front panel.
View lock status
X
Exe
X#]
Show lock status.
N
X!
= Specific input number, 0-5 and 7
X#
= Status: 0 = off/disable (default), 1 = on/enable
X$
= Bass and treble adjustment range; 0-14, in 1.5 dB increments, e.g., 0 = -10.5,...5 = -3.0,...14 = +10.5 dB
X%
= Bass and treble reading: - 10.5 to +10.5 dB
X^
= Volume, 0-100 (default = 50)
X*
= 0 – 18, input attenuation adjustment range, 0 through -18 dB, in 1 dB steps
X(
= Input gain and attenuation, in dB, -18 to +24