Fujitsu M8000 Server User Manual


 
11-14 SPARC Enterprise M8000/M9000 Servers Service Manual June 2010
11. Mount the replacement XSCFU by following the removal instructions in Step 8
and Step 9 in reverse order. Align the XSCFU with the slot guides, insert it
carefully, and secure it firmly.
Push the levers as far as they will go, and then push the knob screws on the
eject/lock levers to lock them in position. When the knob screws remain in
position, the XSCF unit is securely mounted.
Caution – Do not forcibly push the XSCFU in when inserting it. If the XSCFU is
forcibly inserted despite the presence of any obstruction in a slot or any problems
with the connector pin, serious damage may result.
Caution – Do not forcibly push the cable in when inserting it. If the cable is forcibly
inserted despite the presence of any obstruction in a slot or any problems with the
connector pin, serious damage may result.
12. Switch on all main line switches for the AC section (ACS) in the power supply
system.
13. Confirm that the XSCF STANDBY LED (green) on the operator panel remains
lit. If it is blinking, wait until it remains lit.
14. Update the XSCF firmware.
In case the version of the firmware on the replaced XSCFU is different from the
version of the original, it is necessary to match the version of the firmware.
For the version matching of firmware, see the SPARC Enterprise
M3000/M4000/M5000/M8000/M9000 Servers XSCF User’s Guide.
15. Set the XSCF clock.
From the terminal connected to XSCF, log in to XSCF and use setdate -s
MMDDhhmmCCYY.ss command to set the current time.
For details of the setdate command, see the SPARC Enterprise
M3000/M4000/M5000/M8000/M9000 Servers XSCF User’s Guide, the SPARC
Enterprise M3000/M4000/M5000/M8000/M9000 Servers XSCF Reference Manual, or
the man page.