Fujitsu M8000 Server User Manual


 
Chapter 2 Product Overview and Troubleshooting 2-39
The following example shows output for one iostat command.
2.9.2 prtdiag Command
The prtdiag command displays configuration and diagnostic information. The
diagnostic information identifies any failed component.
The prtdiag command is located in the
/usr/platform/platform-name/sbin/ directory.
Note – The prtdiag command might indicate a slot number different than that
identified elsewhere in this document. This is normal.
2.9.2.1 Options
TABLE 2-14 describes options for the prtdiag command and how those options can
help troubleshooting.
# iostat -En
c0t0d0 Soft Errors: 0 Hard Errors: 0 Transport Errors: 0
Model: ST3120026A Revision: 8.01 Serial No: 3JT4H4C2
Size: 120.03GB <120031641600 bytes>
Media Error: 0 Device Not Ready: 0 No Device: 0 Recoverable: 0
Illegal Request: 0
c0t2d0 Soft Errors: 0 Hard Errors: 0 Transport Errors: 0
Vendor: LITE-ON Product: COMBO SOHC-4832K Revision: O3K1 Serial
No:
Size: 0.00GB <0 bytes>
Media Error: 0 Device Not Ready: 0 No Device: 0 Recoverable: 0
Illegal Request: 0 Predictive Failure Analysis: 0
TABLE 2-14 Options for prtdiag
Option Description How It Can Help
No option Lists components. Identifies CPU information, memory configuration,
mounted PCI cards, OBP version number, mode switch
status, and CPU operational mode.
-v Verbose mode. Provides the same information as "no option." Additionally,
lists the detail information of PCI cards.