Fujitsu M8000 Server User Manual


 
2-36 SPARC Enterprise M8000/M9000 Servers Service Manual June 2010
2.8.3.2 fmadm faulty Command
The fmadm faulty command can be used mainly to identify the status of faulty
components.
In the following example, the PCI card is degraded and associated with the
following UUID 49847040-ce57-e453-9adc-fe66c7c65384. Also, the "faulted"
state may be displayed.
Note – The error information remains in the Solaris OS even when replacement of
the faulty component is completed. Identify the UUID by executing the fmadm
faulty command, and reset the error information by executing the fmadm repair
command with the UUID specified.
2.8.3.3 fmadm repair Command
The fmadm repair command can be used to reset the error information for a faulty
component in the Solaris OS.
# fmadm config
MODULE VERSION STATUS DESCRIPTION
cpumem-diagnosis 1.5 active UltraSPARC-III/IV CPU/Memory Diagnosis
cpumem-retire 1.0 active CPU/Memory Retire Agent
eft 1.13 active eft diagnosis engine
fmd-self-diagnosis 1.0 active Fault Manager Self-Diagnosis
io-retire 1.0 active I/O Retire Agent
syslog-msgs 1.0 active Syslog Messaging Agent
# fmadm faulty
STATE RESOURCE / UUID
----- --------------------------------------------------
degraded dev:////pci@2,600000
49847040-ce57-e453-9adc-fe66c7c65384
# fmadm repair 49847040-ce57-e453-9adc-fe66c7c65384
fmadm: recorded repair to 3de29de5-6332-ec64-9b49-bacc739fe3c3