E-1
APPENDIX
E
XSCF Unit Replacement When XCP
1040 or 1041 Is in the Server
The server must be updated to XCP 1050 or later.
Note – XCP 1050 or later cannot be downgraded to XCP 1040 or XCP 1041.
1. Turn off all domains.
2. Turn the Mode switch to Service.
3. Turn off all main line switches.
4. Replace XSCFU#0 with spare material, and reconnect cables to XSCFU#0.
5. Extract XSCFU#1
6. Turn on all main line switches.
The following log may be recorded, but you can ignore it:
7. Set the date and time on the XSCFU.
8. Turn off all main line switches.
9. Reinsert the XSCFU#1 that you extracted in Step 5.
10. Turn off all of the server’s main line switches for 30 seconds.
11. After 30 seconds, turn the main line switches back on.
XSCF> showlogs error -r -M
Date: Oct 01 18:02:06 JST 2007 Code: 80008000-55000000-010a101f00000000
Status: Alarm Occurred: Oct 01 18:02:06.604 JST 2007
FRU: /XSCFU_B#1
Msg: XSCF_B shortage